Water is widely used in pharmaceutical manufacturing – either as a raw material, as an ingredient, or as a final product. Water is also used for rinsing equipment or for the preparation of disinfectants and detergents…
These applications require pharmaceutical-grade water to be used, which is water that has been through a chemical purification step. Purification is undertaken so that the water is free of substances that might cause interaction with drug substances, as well as to obtain water of an appropriate microbiological standard.
Microbiological risks are ever present with water systems. Risks can arise through poorly maintained water generation systems, through badly designed distribution networks (such as the presence of dead legs), or at user outlets (where ineffective tubing management can lead to contamination). Weaknesses in water systems are exacerbated by microorganisms being ubiquitous and varied in their ability to survive and grow under different conditions. Therefore, monitoring pharmaceutical-grade water systems for bioburden is important.
We are concerned with two primary types of water: purified water and water for injections (WFI). Both types should be assessed for bioburden, while WFI also requires bacterial endotoxin testing. This article addresses methods for bioburden testing.
Are you looking to explore how lipid formulations in softgels can enhance drug absorption and bioavailability. Register for our upcoming webinar to find out!
3 September 2025 | 3:00 PM BST | FREE Webinar
This webinar will delve into the different types of lipid formulations, such as solutions, suspensions, emulsions, and self-(micro)emulsifying systems. Applications span diverse therapeutic areas including HIV therapy, oncology, immunosuppressants, and emerging treatments like medicinal cannabis (eg, CBD).
What You’ll Learn:
Lipid formulation development and screening tools for optimisation
Key steps in scale-up and industrialisation to ensure consistency and efficiency
Impact of lipid-based softgels on drug delivery and patient outcomes.
Unlike chemical analysis (conductivity or the examination of total organic carbon), microbiological assessment using conventional culture-based methods is less accurate and the result obtained far more slowly. While rapid microbiological methods are gradually being implemented (such as ATP bioluminescence techniques, or the use of fluorescent DNA-specific dyes) most microbiological assessments of pharmaceutical grade water are reliant upon cultural methods.1 This means bioburden results are not available until several days have elapsed2, a fact which places considerable emphasis on good design principles but means that the reaction to an out-of-trend situation is often very slow.
This article assesses the different approaches that can be used for the microbiological assessment of pharmaceutical water systems, examining both cultural based methods and alternative methods, arguing that rapid methods offer significant advantages.
Cultural methods
The most common means to assess the microbial count from a sample of water is a culture-based method. This is through the deployment of a total microbial aerobic count (TAMC) method, either pour plate or, preferably, membrane filtration (due to the larger sample size). In the European Pharmacopeia, the method, sample size, culture medium and incubation conditions are pre-set for purified water and WFI. But in the United States Pharmacopeia (information chapter <1231>) these conditions are left to be determined by the user.
The culture medium recommended in the European Pharmacopeia is R2A (Reasoner’s 2A agar), which replaced a more nutritious medium through a monograph update in 2002. R2A was designed for performing the heterotrophic plate count for water samples. R2A is a nutritionally reduced media (in that the levels of peptone, yeast extract and dextrose are considerably lower than standard plate count media like TSA), which aids the recovery of stressed or sub-lethally damaged microorganisms.3 R2A was designed to be used with a longer incubation time (relative to the more commonly used TSA) at a temperature of around 20C. Oddly, the European Pharmacopeia requires the medium to be used at a higher temperature (30-35C) and for a relatively short incubation time (five days) – a requirement which runs counter to the theoretical design and initial application of the medium. It is uncertain why this is so, other than the time and temperature combination did not change when the medium was supplemented with the 2002 revision.
The USP is not prescriptive in terms of microbiological culture media and incubation times (indeed it also paves the way for adopting rapid microbiological methods, as discussed below). The USP discusses the merits of various agars, including the more nutrient-rich Plate Count Agar (PCA) for the isolation of heterotrophic bacteria and low-nutrient media like R2A (for the isolation of slow-growing ‘oligotrophic’ bacteria). The USP states that an evaluation must be undertaken in order to select the most appropriate microbiological agar for the intended system. The point made is that all water systems differ based on geography and seasonality, therefore a universal approach is probably inappropriate.
In addition, the USP does not specify any action levels, whereas the European Pharmacopeia does, using the specification of 10 CFU/100ml for WFI and 1,000 CFU/ml for purified water. This approach of not setting action levels is similar to the USP aseptic processing chapter <1116>, where the 2012 revision removed numerical action levels and proposed a contamination rate metric should be used instead to count non-zero events.4 While the USP approach for microbiological water assessment makes sense (different sources of water and manufacturing processes will vary and risks will vary), this method makes things more difficult for internationally comparative quality standards to be maintained.
As well as the differences between culture media, and the lack of any universal medium or incubation conditions, it is important to note that any microbiological medium will have inherent variability. This is because key ingredients – peptones – are derived from plant and animal material, meaning they are not chemically defined. In addition, the ingredients can be affected by other factors like the mineral content of water.
Some organisations, depending on the quality of the in-coming water, also undertake specific pathogen testing. The pathogens selected will depend on risk assessment and the risk of transfer to the purified water system. An example is a test for total coliforms, since these are indicators of organic pollution in potable water. For instance, the bacterium Escherichia coli indicates pollution of human or animal faecal origin. Using cultural methods, the use of selective agars or an enrichment step represents the primary test method.
Rapid microbiological methods
Concerns about the limitations of conventional methods and culture media, as well as the possibilities afforded by technological advances, have led to a new(ish) generation of rapid and alternative microbiological methods. Issues with culture-based methods include the time to result and accuracy. The issue of accuracy (as expressed as recoverability) is compounded by the fact that many microorganisms living in water are not culturable on standard agar or broth, either due to their inherent nature and adaptability, or as a result of the stresses associated with low nutrient environments. Organisms in this state are referred to as ‘viable but non-culturable’ or, more accurately, ‘active but non-culturable’.5
Rapid and alternative microbiological methods are based on technologies that are either growth-based, viability-based, or based on surrogate-based cellular markers for a microorganism (such as nucleic acid-based, fatty acid-based). These methods tend to be automated and offer a faster time-to-result, as well as increased sensitivity. A selection of these methods is discussed below.
ATP bioluminescence technology
This technique utilises an enzymatic reaction as the detection signal. Adenosine triphosphate (ATP), a component of all living microorganisms, is allowed to react with the firefly enzyme luciferase. The enzyme reagent catalyses the conversion of microbial ATP into adenosine diphosphate (ADP) and light with the resulting light flash measured using a luminometer. Systems based on ATP technology capture light signals emitted from the microorganisms captured on a membrane after the water has been filtered, using specialised imaging technology. To ensure that there is sufficient ATP present for detection, an enrichment step requiring 24-hour incubation is used.6 However, by replacing colony formation as the detection signal with an enzymatic reaction, considerable time savings are achieved compared to conventional methods.
Samples are read by processing using image analysis software; here the bioluminescence from each microbial (or micro-colony, where cells amass together) is intensified several thousand-fold. The software counts the numbers of microorganisms present and provides a result per unit of volume.
Light scattering
Light-scattering methods can be used for the detection of water pathogens. This is a form of flow cytometry. With this method, as the slip stream passes through the flow cell, it also passes through a laser beam. When particles of 0.4 microns to 10 microns in size are present, a specific multi-angle light-scatter pattern will be captured by the unit’s photodetector. This pattern is then analysed and compared to a bio-optical signatures database using proprietary algorithms. From this analysis, relative concentration is calculated and detected particles are classified as bacteria, spore, protozoan or ‘unknown’. The system does not provide viability data as it cannot differentiate between live and dead microorganisms. To carry out microbial identification, a portion of the sample must be retained and cultured.
Counting fluorescently-labelled cells
Direct counting of fluorescently labelled microbial cells has been available in its simplest form since the availability of ultraviolet light microscopes. Essentially, cells are stained with a fluorescent, DNA-specific dye, such as DAPI (4′-6-diamidino-2-phenylindole) and are counted. Marine biology and other environmental studies have repeatedly demonstrated that this technique produces results that are 100- to 1,000-fold higher than plate count methods. The reason for this is partly the phenomenon of viable but non-culturable (VBNC) microorganisms, and partly the fact that dead microorganisms are labelled and counted. The major drawbacks of this type of direct counting are firstly the inability to distinguish the living and the dead, and secondly, the sheer drudgery involved in manual counting. This can be overcome through automation and the use of fluorescent viability markers to obtain total viable counts within a few hours and without the need for growth.
Such systems work by first capturing the microorganisms on a 0.4µm membrane filter and then labelling them with a fluorescein ester. In the esterified form the stain does not fluoresce, but once the ester is cleaved fluorescence is exhibited. The stain diffuses passively across the cell membrane, and in viable cells it is cleaved by ubiquitous esterase enzyme present in all micro-microorganisms. Provided that the membrane is intact, the fluorescein accumulates within the cell. A laser spot 6µm in diameter scans the entire surface of the filter, stimulating fluorescence from any labelled object, and two photomultiplier tubes detect the light emitted. Software capable of analysing the pattern of fluorescence determines the nature of any labelled particle detected. Results are usually reported as a scan map identifying the location of each microorganism counted on the filter. An epifluorescent microscope with an automated stage can be linked to provide visual confirmation of the results.7
Specific pathogen testing
Methods for specific pathogen testing include enzyme/substrate methods based on
colourimetric or fluorimetric assays, which rely on specific enzymatic activities. Such methods provide an answer within 18 hours or shorter should they be used with high-sensitivity fluorescence detection instruments. Alternatively, antibody-based approaches that utilise the specific binding affinities of antibodies to specific antigens can be used. These can be detected using enzyme-linked immunosorbent assay (ELISA) techniques. There are also genetic methods, like quantitative polymerase chain reaction (PCR), for which
Various detection kits targeting waterborne pathogens are available, which utilise genetic methods like quantitative polymerase chain reaction (PCR) or DNA microarrays (probe molecules composed of short single-stranded nucleic acid (DNA or RNA) or oligonucleotides with known sequences.8
Method qualification
It is important that rapid methods are qualified to show they are suitable for use as alternatives to the compendia methods. Qualification, in terms of microbiological tests, aims to determine whether the sample to be examined has any inherent anti-microbial properties and whether the incubation and growth conditions can recover microorganism that may be present to an acceptable level. Approaches to method qualification and suitable parameters have been extensively covered by authors like Miller.9
Summary
This article has assessed the primary methods for examining of pharmaceutical grade water, considering both cultural techniques and rapid (alternative) microbiological methods. The limitations (not to mention compendia disagreement) of cultural methods are apparent. Nevertheless, cultural methods remain predominant for the assessment of pharmaceutical water systems. In contrast, several rapid methods – of which some of the technologies have been described here – offer greater advantages in terms of accuracy and time to result. There are signs that a shift towards more rapid and accurate methods is occurring, especially as technology develops.
Although the approach to testing is important, it represents just one facet of microbiological control of water systems. Arguably an equal, if not greater, emphasis should be placed on systems design and control. It is also important that the samples taken are representative and taken aseptically using appropriate sterile containers.
Biography
DR TIM SANDLE’s primary role is Head of Microbiology at Bio Products Laboratory, a sterile products manufacturer. In addition, he is a tutor with the School of Pharmacy and Pharmaceutical Sciences, University of Manchester, for the university’s pharmaceutical microbiology MSc course, and a longstanding committee member of the pharmaceutical microbiology society Pharmig.
References
Cundell A, Gordon O, Haycocks N, et al. Novel Concept for Online Water Bioburden Analysis: Key Considerations, Applications, and Business Benefits for Microbiological Risk Reduction. American Pharmaceutical Review 2013;16(3):26-31.
Sandle T. Characterizing the Microbiota of a Pharmaceutical Water System – A Metadata Study. SOJ Microbiol Infect Dis. 2015;3(2):1-8
Reasoner D, Geldrich E. A new medium for the enumeration and subculture of bacteria from potable water. Applied Environmental Microbiology. 1985;49:1–7.
Sandle T. Microbiological control and monitoring of cleanrooms: Revised USP <1116> chapter. Clean Air and Containment Review. 2012;11:22-23
Sandle T. A Review of Cleanroom Microflora: Types, Trends, and Patterns. PDA Journal of Pharmaceutical Science and Technology. 2011;65(4):392–403.
Marino G, Maier C, Cundell AM. A Comparison of the MicroCount™ Digital System to Plate Count and Membrane Filtration Methods for the Enumeration of Microorganisms in Water for Pharmaceutical Purposes. PDA J Pharm Sci Technol. 2000;54(3).
Costanzo SP, Borazjani RN, McCormick PJ. Validation of the Scan RDI for Routine Microbiological Analysis of Process Water. PDA J Pharm Sci Technol. 2002;56(4).
Miller, MJ. A Fresh Look at USP <1223> Validation of Alternative Microbiological Methods and How the Revised Chapter Compares with PDA TR33 and the Proposed Revision to Ph. Eur. 5.1.6. American Pharmaceutical Review. 2015;18(5):22-35.
Adler M, Wacker R, Niemeyer CM. Sensitivity by combination: immuno-PCR and related technologies. Analyst. 2008;133(6):702-18.
This website uses cookies to enable, optimise and analyse site operations, as well as to provide personalised content and allow you to connect to social media. By clicking "I agree" you consent to the use of cookies for non-essential functions and the related processing of personal data. You can adjust your cookie and associated data processing preferences at any time via our "Cookie Settings". Please view our Cookie Policy to learn more about the use of cookies on our website.
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorised as ”Necessary” are stored on your browser as they are as essential for the working of basic functionalities of the website. For our other types of cookies “Advertising & Targeting”, “Analytics” and “Performance”, these help us analyse and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these different types of cookies. But opting out of some of these cookies may have an effect on your browsing experience. You can adjust the available sliders to ‘Enabled’ or ‘Disabled’, then click ‘Save and Accept’. View our Cookie Policy page.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Cookie
Description
cookielawinfo-checkbox-advertising-targeting
The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Advertising & Targeting".
cookielawinfo-checkbox-analytics
This cookie is set by GDPR Cookie Consent WordPress Plugin. The cookie is used to remember the user consent for the cookies under the category "Analytics".
cookielawinfo-checkbox-necessary
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-performance
This cookie is set by GDPR Cookie Consent WordPress Plugin. The cookie is used to remember the user consent for the cookies under the category "Performance".
PHPSESSID
This cookie is native to PHP applications. The cookie is used to store and identify a users' unique session ID for the purpose of managing user session on the website. The cookie is a session cookies and is deleted when all the browser windows are closed.
viewed_cookie_policy
The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
zmember_logged
This session cookie is served by our membership/subscription system and controls whether you are able to see content which is only available to logged in users.
Performance cookies are includes cookies that deliver enhanced functionalities of the website, such as caching. These cookies do not store any personal information.
Cookie
Description
cf_ob_info
This cookie is set by Cloudflare content delivery network and, in conjunction with the cookie 'cf_use_ob', is used to determine whether it should continue serving “Always Online” until the cookie expires.
cf_use_ob
This cookie is set by Cloudflare content delivery network and is used to determine whether it should continue serving “Always Online” until the cookie expires.
free_subscription_only
This session cookie is served by our membership/subscription system and controls which types of content you are able to access.
ls_smartpush
This cookie is set by Litespeed Server and allows the server to store settings to help improve performance of the site.
one_signal_sdk_db
This cookie is set by OneSignal push notifications and is used for storing user preferences in connection with their notification permission status.
YSC
This cookie is set by Youtube and is used to track the views of embedded videos.
Analytics cookies collect information about your use of the content, and in combination with previously collected information, are used to measure, understand, and report on your usage of this website.
Cookie
Description
bcookie
This cookie is set by LinkedIn. The purpose of the cookie is to enable LinkedIn functionalities on the page.
GPS
This cookie is set by YouTube and registers a unique ID for tracking users based on their geographical location
lang
This cookie is set by LinkedIn and is used to store the language preferences of a user to serve up content in that stored language the next time user visit the website.
lidc
This cookie is set by LinkedIn and used for routing.
lissc
This cookie is set by LinkedIn share Buttons and ad tags.
vuid
We embed videos from our official Vimeo channel. When you press play, Vimeo will drop third party cookies to enable the video to play and to see how long a viewer has watched the video. This cookie does not track individuals.
wow.anonymousId
This cookie is set by Spotler and tracks an anonymous visitor ID.
wow.schedule
This cookie is set by Spotler and enables it to track the Load Balance Session Queue.
wow.session
This cookie is set by Spotler to track the Internet Information Services (IIS) session state.
wow.utmvalues
This cookie is set by Spotler and stores the UTM values for the session. UTM values are specific text strings that are appended to URLs that allow Communigator to track the URLs and the UTM values when they get clicked on.
_ga
This cookie is set by Google Analytics and is used to calculate visitor, session, campaign data and keep track of site usage for the site's analytics report. It stores information anonymously and assign a randomly generated number to identify unique visitors.
_gat
This cookies is set by Google Universal Analytics to throttle the request rate to limit the collection of data on high traffic sites.
_gid
This cookie is set by Google Analytics and is used to store information of how visitors use a website and helps in creating an analytics report of how the website is doing. The data collected including the number visitors, the source where they have come from, and the pages visited in an anonymous form.
Advertising and targeting cookies help us provide our visitors with relevant ads and marketing campaigns.
Cookie
Description
advanced_ads_browser_width
This cookie is set by Advanced Ads and measures the browser width.
advanced_ads_page_impressions
This cookie is set by Advanced Ads and measures the number of previous page impressions.
advanced_ads_pro_server_info
This cookie is set by Advanced Ads and sets geo-location, user role and user capabilities. It is used by cache busting in Advanced Ads Pro when the appropriate visitor conditions are used.
advanced_ads_pro_visitor_referrer
This cookie is set by Advanced Ads and sets the referrer URL.
bscookie
This cookie is a browser ID cookie set by LinkedIn share Buttons and ad tags.
IDE
This cookie is set by Google DoubleClick and stores information about how the user uses the website and any other advertisement before visiting the website. This is used to present users with ads that are relevant to them according to the user profile.
li_sugr
This cookie is set by LinkedIn and is used for tracking.
UserMatchHistory
This cookie is set by Linkedin and is used to track visitors on multiple websites, in order to present relevant advertisement based on the visitor's preferences.
VISITOR_INFO1_LIVE
This cookie is set by YouTube. Used to track the information of the embedded YouTube videos on a website.