The first part of an in-depth article on Quality by Design (QbD), published in European Pharmaceutical Review in December 2016, focused on designing quality in to a pharmaceutical drug product by considering dosage form design, and understanding the importance of active pharmaceutical ingredients’ (APIs’) and excipients’ properties.
In the second instalment of this two-part series, the possibilities for implementing manufacturing efficiencies, particularly those concerned with process monitoring and control, will be explored, thus providing the reader with the rest of the picture on how generics manufacturers might take advantage of QbD concepts in order to gain competitive edge.
Solid dosage form manufacture Yu et al provide a comprehensive listing of material and quality attributes, as well as processing parameters, that are relevant to operations for the manufacture of tablets (or capsules) and that merit programmes to characterise behaviour from a QbD perspective1. The following commonly used operations are considered here:
Blending
Size reduction (drug and/or granulated material)
Granulation (size enlargement) or densification
Drying (removal of water or other solvent)
Compaction/compression (tablet or compact formation)
Coating tablets or granules.
Such operations have historically been controlled by defining the equipment type, operating conditions and time of operation. However, variations in input materials (drug, excipients and process intermediates), scale of operation, environmental conditions and other factors, such as ‘wear and tear’ of equipment, could cause excessive (‘over’) or ‘under’-processing, thus compromising the attributes of output materials. Novel process analytical technologies (PAT) now promise to change processing paradigms by using online process monitoring capability with automatic termination of the process or sub- process when the requisite material attributes are attained. Possibilities associated with common process operations, or their subsets, are presented here as examples. They do not reflect the totality of emerging opportunities in a rapidly changing environment, particularly with respect to instrumentation for online monitoring. For instance, process analysers are mainly spectroscopic at present, but chromatography-based systems are also emerging. The potential for at-line, in-line or on-line measurements to monitor and assure quality can contribute to flexible and more reliable manufacturing operations and reduced energy consumption, as well as decreasing the need for end-product testing2.
Are you looking to explore how lipid formulations in softgels can enhance drug absorption and bioavailability. Register for our upcoming webinar to find out!
3 September 2025 | 3:00 PM BST | FREE Webinar
This webinar will delve into the different types of lipid formulations, such as solutions, suspensions, emulsions, and self-(micro)emulsifying systems. Applications span diverse therapeutic areas including HIV therapy, oncology, immunosuppressants, and emerging treatments like medicinal cannabis (eg, CBD).
What You’ll Learn:
Lipid formulation development and screening tools for optimisation
Key steps in scale-up and industrialisation to ensure consistency and efficiency
Impact of lipid-based softgels on drug delivery and patient outcomes.
Magnesium stearate is employed extensively as a lubricant in tablet manufacture. Many factors contribute to the variability of this otherwise excellent lubricant. Blend time is usually a critical process parameter. A blend time that is too long (‘over-lubrication’) leads to weak compact formation. It may also retard drug release. Under-lubrication generally causes die wall friction and tablet defects (‘sticking’ and ‘picking’).
Near-infrared spectroscopy (NIR) has been successfully utilised to monitor, on a continuous and non-invasive basis, the incorporation (blend homogeneity) of magnesium stearate in granule blends for tableting3. In one such study, spectra were captured for each rotation of the blender to monitor such homogeneity. Material was also sampled by conventional means (sample thief), dispersion homogeneity being determined by conventional analysis (atomic absorption spectroscopy). Figure 1 shows traces of standard deviations for lubricant distribution as a function of the number of blender rotations during a six minute time period (earlier sampling at 1.5 minutes/26 rotations showed that dispersion homogeneity did not meet United States Pharmacopoeia standards). The results correlated with homogeneity values determined by atomic absorption spectroscopy.
Figure 1: Relationship between number of blender rotations and magnesium stearate dispersion homogeneity by NIR analysis (reproduced with permission from reference 7)
A thermal effusivity technique has also been utilised to monitor magnesium stearate incorporation in a blend for tableting. When this measurement is constant, the relative standard deviation is minimal, indicating that the blend is homogeneous4. The technique requires that the sample be static for a brief period, requiring some form of ‘bypass’ in a continuously moving powder bed, or that the mixing process be briefly stopped.
In essence, PAT can play useful roles in optimising lubricant incorporation in blends for tableting, avoiding under- or over-blending that can compromise compaction and tablet quality. This could conceivably allow batch- or equipment-specific blend times, for instance, when equipment change is warranted due to changed off-take forecasts. The technique also has potential for qualifying alternative sources of lubricant where blend time might need to be modified for optimum lubrication.
Size reduction and enlargement
A drug may need to be size-reduced to improve its biopharmaceutical performance (e.g., micronisation), rendering a material physically more homogeneous (by breaking up lumps or aggregates) or to facilitate homogenous admixture with other components. Excipients may also, on occasion, need to be size-reduced (for instance, lactose in pulmonary inhalation products). Size enlargement processes (granulation) are also common, as in granule-forming operations. Process analytical techniques to continuously monitor particle size, be it reduction or enlargement, are considered together here for the sake of clarity, particle size being the common material attribute.
Laser diffraction methods based on estimates of mean particle diameters have been used to monitor particle growth (granule formation) during fluid-bed granulation or when coating fluidised particles. The profiles in Figure 2 illustrate the fall-off in small particle counts during processing as they are incorporated in larger (so-called ‘coarse’) granules. Excessive energy consumption is avoided, the process being terminated when the requisite size distribution is achieved.
Drying/solvent removal
The rate and extent of water or organic solvent removal during drying, granulation or coating can be affected by input variables such as temperature, air ‘dryness’, its velocity and the aerodynamics in fluidised systems (as well as time). Relative humidity of input air can vary with time of day, season and geographic location. Thus, output material can be ‘over’ or ‘under-dried’ if process conditions are defined in simplistic time and temperature terms. Inadequate drying could compromise the stability of moisture-sensitive materials while ‘over-drying’ could lead to brittle granules and attrition during subsequent processing. Probes that monitor the relative humidity or temperature of input and output air have historically been used to define the drying end point; a lack of difference between input and output air values being interpreted as indicating that moisture is no longer leaving the material so is effectively ‘dry’. However, such surrogate markers may not always be adequate as rate and extent of drying can be influenced by the aforementioned environmental factors as well as by material bulk density, affecting the rate of water vapour diffusion through the solid being dried. A measure of the ‘true’ moisture content may be required. NIR has the potential to provide real-time monitoring of moisture content, since water exhibits good absorption in the NIR spectral region. It has shown potential in fluid bed granulation5 .
The majority of APIs and excipients absorb NIR radiation. The technique is non-destruc – tive, non-invasive and rapidly generates data. As such it offers much potential for online monitoring of processing and quality attributes, such as blend uniformity or content uniformity in unit dosage forms. It may also be capable of determining the ‘spatial distribution’ of components in the finished product via an imaging technique (‘chemical imaging’)6 . Other vibrational spectroscopy techniques such as mid-infrared or Raman may also be valuable for online monitoring of processes, being non-destructive, speedy and non-invasive. Raman spectroscopy was shown to control tablet coating accuracy and homogeneity for a fixed dose combination product, where one of the drugs was spray-coated onto tablet cores. Content accuracy and uniformity were monitored online, with an automated process endpoint. The technology was robust and scalable from laboratory to industrial scale7 .
Figure 2: Granulation and particle size distribution (Lasentech) after addition of granulating agent
Where possible it could be advantageous to select excipients with spectroscopic characteristics that render them suitable for monitoring techniques such as NIR. Defining suitable process monitoring tests, process control and endpoint requirements are of prime importance during formulation and process development.
There are many design, operational and interpretational complexities associated with process analytical techniques and instrumentation. They may require significant investment in instrumentation, data collection systems, software development for setup and qualification, and for monitoring and maintenance programmes. Calibration and model development to qualify a technique tends to be material and process-specific. Nevertheless, cumulative experiences and advances in analytical instrumentation are likely to reduce complexity, increase robustness and refine interpretative capability. Regulatory agencies encourage investment in such technologies as a means of achieving better control of processes and products. Operational efficiencies, as well as product and process consistency, can benefit from such investments.
Compact formation
Figure 3: Benchtop compaction simulation equipment. Provided by and reproduced with permission of owners
Traditional paradigms concerning tablet compact formation involved monitoring hardness and compact weight, and possibly, friability ‘at line’, to ensure appropriate ruggedness and disintegration properties of the formed compacts. Nowadays, tablet presses are capable of automatic compaction to a defined pressure. If the compression properties of a formulation have been shown to be consistent it is possible to control output parameters such as hardness, friability and disintegration by the input parameter, compression force. However, such relationships can be tablet press-specific and depend on variables such as compression speed, angular velocity (being press size-dependent) and properties of excipients, such as residual moisture content or particle size or shape. Hence, compression behaviours merit periodic confirmation, particularly when qualifying a new source of excipient or active ingredient, or when compaction equipment is changed. Such diligence provides assurance of consistency of input/output relationships, or indicates where re-definition is necessary. Generating such information at large scale would be a demanding exercise.
Fortunately, the compaction process can be considered (in most cases) to be a ‘unit operation’. The advent and use of ‘benchtop compaction simulators now makes it possible to carry out many compression-related studies at laboratory scale. Compression cycles can be programmed to simulate different machine types and variables such as rotational speeds and centrifugal forces.
Ejection force could be monitored to qualify new sources of lubricating agents or different modes of incorporation in blends for compression. Figure 3 provides illustrations of equipment and references their providers.
Cycle time reduction in manufacture and testing
Monitoring and ‘control’ of quality, as previously (and mostly still) practised, can be unwieldy and slow. Monitoring ‘at line’ may mean interrupting the process so that ‘intermediates’ can be tested. Manufacture can accordingly comprise a series of ‘stop and start’ operations. In addition, GMP-based systems invariably require paperbased approval and many signatures. Overall approval times can greatly exceed manufacturing and testing times, even when there are no halts for testing intermediates. The timelines in Table 1 are not uncommon. Re-testing or reworking material prolongs cycle times. Yet, such monitoring and approval systems have done little to reduce product and process defects and recalls.
The QbD insights and PATs that have been briefly discussed here have the potential to provide more reliable processes and eliminate ‘stop/start’ modes of manufacture. This should facilitate the adoption of ‘continuous’ rather than batch manufacture. A well characterised process, with online ‘quality monitoring’ has the potential to greatly reduce cycle time. There is also much scope for innovative solutions to the ‘paper-based bottlenecking’ that contributes to the month- long (or greater) approval times in Table 1. Quality can be checked without interrupting production and aligns well with the concept of real-time release. Linking online monitoring data electronically to a batch review process, with an appropriate e-verdict on findings (or highlighting a potential issue), could substantially reduce review time, much of which is currently taken up by correcting documentation and other errors (with associated need to re-circulate for review and approval).
Table 1: Cycle Time for Manufacture and Approval*
Activity
Time
Batch Manufacture
1 day
Testing
3 days
Approval
– ‘manual’
– 80 pages of records to review
– sequential signatures
40 days
* privately-sourced information
There are many challenges to providing a verdict on overall quality, including analytical techniques, data collection, interpretation, and integration in a holistic way that integrates quality monitoring and control operations. Significant skill-sets and expertise are necessary. This will require substantial staffing as well as investments in facilities and equipment but the rewards can be substantial.
Conclusions
A systematic, science-based strategy for dosage form and process development, rather than an approach based on ‘copying’ the composition of an innovator product, can be a valuable investment in a generic drug development programme. It requires a strategic commitment to developing a QbD-based culture and a technical function resourced to develop the opportunities for efficiencies and savings.
Generics organisations experience time pressures for product filings and approvals. In the United States (depending on the type of abbreviated new drug application [ANDA] filed) a ‘first approval’ gains 180-day exclusivity; price competition then erodes margins. A well-conducted QbD programme, clearly communicated in ANDA filings, could reduce the risk of delayed approvals. It is important, therefore, that sufficient time and resource is allocated to the generation and communication of high-quality QbD information. Regulatory agencies welcome dialogue and discussion on plans and proposals for QbD-associated programmes based on good science. Key agencies also cooperate with each other on pilot projects in promoting the QbD way, such as the parallel assessment initiative.
In closing, it is hoped that some of the observations and thoughts in this two-part article help generics companies to consider appropriate investments with respect to QbD programmes and to reap the benefits of such commitment.
About the authors
Patrick Crowley is a pharmacist by training and has spent his entire career involved in dosage form design, in the UK and USA. He made significant contributions, as Laboratory Scientist and Department Manager, in the development of 21 novel molecular entities to medicinal products. These included novel chemical entities, fermentation products and biopharmaceuticals. He also participated in and managed groups developing innovative line extensions of commercial products that secured intellectual property rights. Since retiring as a Vice President in Pharmaceutical Development at GlaxoSmithKline he has operated as an independent consultant and lectures as a Visiting Professor at The School of Pharmacy, Kings College, London.
Sean McCrossen is a chartered chemist and Fellow of the Royal Society of Chemistry. Sean has worked within the pharmaceutical industry for 30 years, specialising in analytical chemistry, chemical development and product support. Sean runs his own consultancy, specialising in CMC technical development and regulatory services to the pharma industry. He currently is working with worldwide pharma clients, regulatory affairs groups and CMO/CROs on both NCEs and generics.
References
Yu L. Pharmaceutical Quality by Design: Product and Process Development, Understanding and Control. Pharmaceutical Research. 2008; 25 (4) 781-791
Chen Z, Lovett D, Morris J. Process Analytical Technologies and Real Time Process Control. A review of some spectroscopic issues and challenges. Journal of Process Control, Elsevier. 2011
Naicker K, Kilian G, Olivier J. Introducing PAT using NIR Analysis for a Pharmaceutical Blending Process. Pharma Manufacturing. 3rd May 2007
Nakajawa H, et al. Real Time Monitoring of Lubrication Properties of Magnesium Stearate Using NIR Spectrometry and a Thermal Effusivity Sensor. Internat. J. Pharmaceutics. 2013; 441 402-413
Sever NE, et al. Chapter 35 in Process Analytical Technology in Solid Dosage Development and Manufacturing: Developing Solid Oral Dosage Forms: Pharmaceutical Theory and Practice. Elsevier. 2009
Lyon RC, et al. Near Infrared Spectral Imaging for Quality Assurance of Pharmaceutical Products: Analysis of Tablets to Assess Powder Blend Homogeneity. AAPS Pharm Sci Tech. 2002; 3 (3) Art 17
Wirges et al. Monitoring of an Active Coating Process for a Two-layer Tablet-model. Development Strategies. J. Pharm Sci. 2013; 102 (2) 556-566
This website uses cookies to enable, optimise and analyse site operations, as well as to provide personalised content and allow you to connect to social media. By clicking "I agree" you consent to the use of cookies for non-essential functions and the related processing of personal data. You can adjust your cookie and associated data processing preferences at any time via our "Cookie Settings". Please view our Cookie Policy to learn more about the use of cookies on our website.
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorised as ”Necessary” are stored on your browser as they are as essential for the working of basic functionalities of the website. For our other types of cookies “Advertising & Targeting”, “Analytics” and “Performance”, these help us analyse and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these different types of cookies. But opting out of some of these cookies may have an effect on your browsing experience. You can adjust the available sliders to ‘Enabled’ or ‘Disabled’, then click ‘Save and Accept’. View our Cookie Policy page.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Cookie
Description
cookielawinfo-checkbox-advertising-targeting
The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Advertising & Targeting".
cookielawinfo-checkbox-analytics
This cookie is set by GDPR Cookie Consent WordPress Plugin. The cookie is used to remember the user consent for the cookies under the category "Analytics".
cookielawinfo-checkbox-necessary
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-performance
This cookie is set by GDPR Cookie Consent WordPress Plugin. The cookie is used to remember the user consent for the cookies under the category "Performance".
PHPSESSID
This cookie is native to PHP applications. The cookie is used to store and identify a users' unique session ID for the purpose of managing user session on the website. The cookie is a session cookies and is deleted when all the browser windows are closed.
viewed_cookie_policy
The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
zmember_logged
This session cookie is served by our membership/subscription system and controls whether you are able to see content which is only available to logged in users.
Performance cookies are includes cookies that deliver enhanced functionalities of the website, such as caching. These cookies do not store any personal information.
Cookie
Description
cf_ob_info
This cookie is set by Cloudflare content delivery network and, in conjunction with the cookie 'cf_use_ob', is used to determine whether it should continue serving “Always Online” until the cookie expires.
cf_use_ob
This cookie is set by Cloudflare content delivery network and is used to determine whether it should continue serving “Always Online” until the cookie expires.
free_subscription_only
This session cookie is served by our membership/subscription system and controls which types of content you are able to access.
ls_smartpush
This cookie is set by Litespeed Server and allows the server to store settings to help improve performance of the site.
one_signal_sdk_db
This cookie is set by OneSignal push notifications and is used for storing user preferences in connection with their notification permission status.
YSC
This cookie is set by Youtube and is used to track the views of embedded videos.
Analytics cookies collect information about your use of the content, and in combination with previously collected information, are used to measure, understand, and report on your usage of this website.
Cookie
Description
bcookie
This cookie is set by LinkedIn. The purpose of the cookie is to enable LinkedIn functionalities on the page.
GPS
This cookie is set by YouTube and registers a unique ID for tracking users based on their geographical location
lang
This cookie is set by LinkedIn and is used to store the language preferences of a user to serve up content in that stored language the next time user visit the website.
lidc
This cookie is set by LinkedIn and used for routing.
lissc
This cookie is set by LinkedIn share Buttons and ad tags.
vuid
We embed videos from our official Vimeo channel. When you press play, Vimeo will drop third party cookies to enable the video to play and to see how long a viewer has watched the video. This cookie does not track individuals.
wow.anonymousId
This cookie is set by Spotler and tracks an anonymous visitor ID.
wow.schedule
This cookie is set by Spotler and enables it to track the Load Balance Session Queue.
wow.session
This cookie is set by Spotler to track the Internet Information Services (IIS) session state.
wow.utmvalues
This cookie is set by Spotler and stores the UTM values for the session. UTM values are specific text strings that are appended to URLs that allow Communigator to track the URLs and the UTM values when they get clicked on.
_ga
This cookie is set by Google Analytics and is used to calculate visitor, session, campaign data and keep track of site usage for the site's analytics report. It stores information anonymously and assign a randomly generated number to identify unique visitors.
_gat
This cookies is set by Google Universal Analytics to throttle the request rate to limit the collection of data on high traffic sites.
_gid
This cookie is set by Google Analytics and is used to store information of how visitors use a website and helps in creating an analytics report of how the website is doing. The data collected including the number visitors, the source where they have come from, and the pages visited in an anonymous form.
Advertising and targeting cookies help us provide our visitors with relevant ads and marketing campaigns.
Cookie
Description
advanced_ads_browser_width
This cookie is set by Advanced Ads and measures the browser width.
advanced_ads_page_impressions
This cookie is set by Advanced Ads and measures the number of previous page impressions.
advanced_ads_pro_server_info
This cookie is set by Advanced Ads and sets geo-location, user role and user capabilities. It is used by cache busting in Advanced Ads Pro when the appropriate visitor conditions are used.
advanced_ads_pro_visitor_referrer
This cookie is set by Advanced Ads and sets the referrer URL.
bscookie
This cookie is a browser ID cookie set by LinkedIn share Buttons and ad tags.
IDE
This cookie is set by Google DoubleClick and stores information about how the user uses the website and any other advertisement before visiting the website. This is used to present users with ads that are relevant to them according to the user profile.
li_sugr
This cookie is set by LinkedIn and is used for tracking.
UserMatchHistory
This cookie is set by Linkedin and is used to track visitors on multiple websites, in order to present relevant advertisement based on the visitor's preferences.
VISITOR_INFO1_LIVE
This cookie is set by YouTube. Used to track the information of the embedded YouTube videos on a website.